    The RD16AY36AJVCA is a 3-ton outdoor heat pump built for larger homes or multi-room applications. It’s designed to condition spaces between 1,500 and 1,800 square feet and integrates into split systems with compatible indoor units. The unit features a single-stage compressor and uses R-454B refrigerant, aligning with current efficiency and environmental standards. Its side-discharge configuration makes it ideal for installations where space or sound restrictions are a concern. The cabinet is designed for easy service access, and the unit performs reliably across seasons. Whether used in a retrofit or new build, it offers dependable heating and cooling without unnecessary complexity.

    Specifications

    • BrandFriedrich
    • Airflow (CFM)2820
    • Compressor TypeTwin BLDC Rotary Inverter
    • ConnectivityBluetooth 5.1
    • Depth (In.)19.80 (19 4/5)
    • Fan TypePropeller Fan
    • Height (In.)31.80 (31 4/5)
    • Liquid Line Size (In.)0.375 (3/8)
    • Low Power Sound Pressure Level (dBa)50
    • Operating Temperature Range (F) -22-70 F (-30-21 C)
    • Phase1
    • RefrigerantR454B
    • Shipping Weight (lbs)272
    • Sound Pressure Level (dBa)58
    • Valve Connection TypeFront Sealing
    • Weight (lbs)230
    • Width (In.)40.40 (40 2/5)
    • ManufacturerFriedrich Air Conditioning
    • Nominal Capacity (Tons)3
    • Compressor StagesVariable Speed
    • Communication AbilityCommunicating
    • Cabinet MaterialSteel
    • Capacity (Btu/Hr)36,000
    • CertificationsENERGY STAR Certified
    • Compressor DesignTwin BLDC Rotary Inverter
    • Compressor Locked Rotor Amps @ 208/230 V52 A
    • Compressor Rated Load Amps @ 208/230 V8.4 A
    • Energy Efficiency Rating (SEER2)17
    • Fan Motor Full Load Amps @ 208/230 V1.6 A
    • Maximum Fuse Amps35.0 A
    • Minimum Circuit Ampacity19.0
    • Outdoor Unit Liquid Line Size (In.)0.375 (3/8)
    • Refrigerant Charge (lbs)5-1/2
    • Suction Line Size (In.)0.75 (3/4)

    Disclaimer