Description
2.5 Ton CAC Universal Outdoor Heat Pump Unit, 30,000 BTU/Hr Nominal Capacity, R410A, 208-230/1/60
Documents
There are no documents available.
Specifications
- BrandSamsung
- Energy Efficiency Rating (EER)10.4 EER with AC030NN4DCH/AA, 10 EER with AC030MNHDCH/AA, 10.15 with AC030KNZDCH/AA, 9.5 EER with AC030MNTDCH/AA, 10.4 EER with AC030KN4DCH/AA
- Energy Efficiency Rating (SEER)18 to 18.99, 18.4 SEER with AC030MNHDCH/AA, 19.6 SEER with AC030KNZDCH/AA, 19.5 SEER with AC030MNTDCH/AA, 19.2 SEER with AC030NN4DCH/AA or AC030KN4DCH/AA, 19 to 19.99
- Liquid Line Size (In.)3/8
- Sound Pressure Level (dBa)50/52
- ZoningSingle-Zone
- Height (In.)39-11/16
- Width (In.)37
- Depth (In.)13
- Capacity (Btu/Hr)30,000
- Compatible Indoor Unit(s) - Air HandlerAC030KNZDCH/AA
- Compatible Indoor Unit(s) - CassetteAC030KN4DCH/AA, AC030NN4DCH/AA
- Compatible Indoor Unit(s) - Ducted ConcealedAC030MNHDCH/AA
- Compatible Indoor Unit(s) - Wall MountAC030MNTDCH/AA
- Cooling Airflow H/M/L/SL (CFM)947/918/1006 with AC030KNZDCH/AA, 671/724/777 with AC030MNTDCH/AA, 632/741/904 with AC030KN4DCH/AA, 590/715/840 with AC030NN4DCH/AA, 671/777/883 with AC030MNHDCH/AA
- Maximum Fuse Amps30.00A
- Maximum Lineset Length (Ft)164
- Modified Outdoor Cooling Temperature Range0 to 115 F (-18 to 46 C) Matched with AC030MNTDCH/AA, AC030MNHDCH/AA, AC030NN4DCH/AA, AC030KN4DCH/AA or AC030KNZDCH/AA (Wind Baffle Required)
- Nominal Capacity (Tons)2-1/2
- Outdoor Heating Temperature Range-4 to 76 F (-20 to 24 C) Matched with AC030MNTDCH/AA, AC030MNHDCH/AA, AC030NN4DCH/AA, AC030KN4DCH/AA or AC030KNZDCH/AA
- Standard Outdoor Cooling Temperature Range23 to 115 F (-5 to 46 C) Matched with AC030MNTDCH/AA, AC030MNHDCH/AA, AC030NN4DCH/AA, AC030KN4DCH/AA or AC030KNZDCH/AA
- Suction Line Size (In.)5/8
- Voltage (V)208-230/1
- Weight (lbs)154