A | Back to Top |
| AC | Air Conditioning | |
| AC | Alternating Current | |
| ACH | Air Changes per Hour | |
| ACM | Asbestos Containing Material | |
| AEE | Association of Energy Engineers | |
| AFD | Adjustable Frequency Drive | |
| AFUE | Annual Fuel Efficiency Ratio | |
| AHU | Air Handling Unit | |
| AI | Analog Input | |
| Anti-Ice Control | same as a freeze stat or encapsulated pressure control | |
| AO | Analog Output | |
| Aquastat | controls the use of a water system. We sell the Honeywell aquastats. You can also use the Ranco ETC series of temp controls. | |
| ASHRAE | American Society of Heating Refrigeration and Air Conditioning Engineers | |
B | | Back to Top |
| B | Boiler | |
| BACnet | A Data Communication Protocol for Building Automation and Control Networks | |
| BAS | Building Automation System | |
| Bazooka | 636 concentric vent kit | |
| BCA | Building Commissioning Association | |
| Bearshit | cork tape | |
| BI | Backward Incline | |
| BI | Binary Input | |
| BO | Binary Output | |
| BSLN | Baseline | |
| BTU | British Thermal Unit | |
| BTUH | Brtish Thermal Units / Hour | |
| BY | Base Year | |
C | | Back to Top |
| Can | a small hermetic compressor | |
| CAV | Constant Air Volume | |
| CD | Cold Deck | |
| CDD | Cooling Degree Days | |
| CEM | Certified Energy Manager | |
| CFC | ChloroFluoroCarbon | |
| CFM | Cubic Feet per Minute | |
| CH | Chiller | |
| CHW | Chilled Water | |
| CHWP | Chilled Water Pump | |
| CHWR | Chilled Water Return | |
| CHWRT | Chilled Water Return Temperature | |
| CHWS | Chilled Water Supply | |
| CHWST | Chilled Water Supply Temperature | |
| CLF | Cooling Load Factor | |
| CLTD | Cooling Load Temperature Difference | |
| COP | Coefficient Of Performance | |
| CRAC | Computer Room Air Conditioner | |
| CT | Cooling Tower | |
| CV | Constant Volume | |
| CVRMSE | Coefficient of Variation of the Root Mean Square of the Error | |
| CWP | Condenser Water Pump | |
| CWR | Condenser Water Return | |
| CWRT | Condenser Water Return Temperature | |
| CWS | Condenser Water Supply | |
| CWST | Condenser Water Supply Temperature | |
| CY | Current Year | |
D | | Back to Top |
| DA | Discharge Air | |
| DB | Data Base | |
| DB | Dry Bulb | |
| DC | Direct Current | |
| DCV | Demand Controlled Ventilation | |
| DD | Degree Day | |
| DDC | Direct Digital Control | |
| DH | Duct Heater | |
| DI | Digital Input | |
| DO | Digital Output | |
| DP | Dew Point | |
| DP | Differential Pressure | |
| DX | Direct Expansion | |
E | | Back to Top |
| EAT | Entering Air Temperature | |
| ECM | Electronically Commutated Motor | |
| ECM | Energy Conservation Measure | |
| ECO | Energy Conservation Opportunity | |
| EDH | Electric Duct Heater | |
| EEM | Energy Efficiency Measure | |
| EER | Energy Efficiency Ratio | |
| EF | Exhaust Fan | |
| Eggcrate | this is a plastic grill material that can replace ceiling tiles. Part Number: 2-4-1/2-ALL | |
| EH | Electric Heater | |
| EMS | Energy Management System | |
| ESCO | Energy Service Company | |
| EUH | Electric Unit Heater | |
| EWT | Entering Water Temperature | |
F | | Back to Top |
| FC | Forward Curve | |
| FCU | Fan Coil Unit | |
| FIM | Facility Improvement Measure | |
| Firecracker | Fan cycling control | |
| FLA | Full Load Amps | |
| Flux | Used to etch metal for filler (solder) to bold | |
| FMS | Facility Management System | |
| FPM | Feet Per Minute | |
| Freeze-Stat | a switch to stop evaporators from icing up. (eg. AE1C-1-ECO or HH) | |
| FW | Feed Water | |
| G | | Back to Top |
| GPM | Gallons Per Minute | |
| GUI | Graphical User Interface | |
| H | | Back to Top |
| HCFC | Hydrochlorocfuorocarbon | |
| HD | Hot Deck | |
| HDD | Heating Degree Days | |
| HEPA | High Efficiency Particulate Arresting | |
| HFC | HydroFluoroCarbon | |
| HHV | Higher Heating Value | |
| HHWP | Heating Hot Water Pump | |
| HHWR | Heating Hot Water Return | |
| HHWS | Heating Hot Water Supply | |
| HL | High Limit | |
| HPS | High Pressure Steam | |
| HR | Heat Recovery | |
| HRU | Heat Recovery Unit | |
| HRV | Heat Recovery Ventilator | |
| HSPF | Heating Seasonal Performance Factor | |
| HVAC | Heating Ventilation and Air Conditioning | |
| HWP | Hot Water Pump | |
| HWR | Hot Water Return | |
| HWS | Hot Water Supply | |
| HWRT | Hot Water Return Temperature | |
| HWST | Hot Water Supply Temperature | |
| HX | Heat Exchanger | |
| I | | Back to Top |
| I/O | Input Output | |
| Inducer Motor | also known as a venter motor. It vents harmful gas out of the furnace through 636 pipe to the outside of the house or building | |
| IAQ | Indoor Air Quality | |
| IPMVP | International Performance Measurement and Verification Protocol | |
| IR | Infra-Red | |
| J | | Back to Top |
| Jellybean | specific style of crimp connector | |
| K | | Back to Top |
| King Valve | The shut off valve on a condensing unit. This where refrigerant is charged and where the line set piping connects to | |
| L | | Back to Top |
| LAT | Leaving Air Temperature | |
| LHV | Lower Heating Value | |
| Line Voltage Thermostat | Used for electrical baseboards or anything using 120/208v to match amperage. Look for these Honeywell items | |
| LL | Low Limit | |
| LON | Local Operating Network | |
| LP | Low Pressure | |
| LPS | Low Pressure Steam | |
| LRA | Locked Rotor Amps | |
| LWBT | Leaving Wet Bulb Temperature | |
| LWT | Leaving Water Temperature | |
| M | | Back to Top |
| M&V | Measurement and Verification | |
| MA | Mixed Air | |
| MAT | Mixed Air Temperature | |
| MCC | Motor Control Center | |
| MUA | Make-up Air Unit | |
| Muffin Motor | 3.3" unit bearing motor eg. R-5411 | |
| MX | Metrix Utility Accounting System | |
| MZ | Multi-Zone | |
| N | | Back to Top |
| NC | Normally Closed | |
| NEMA | National Electrical Manufacturers Association | |
| NO | Normally Open | |
| NPSH | Net Positive Suction Head | |
| O | | Back to Top |
| OA | Outside Air | |
| OAP | Outside Air Percentage | |
| OAT | Outside Air Temperature | |
| OCS | this stands for “Our Compressor Shop”. It is referring to internal purchases used for the business. It was called this when RSL operated their own compressor rebuild shop decades ago | |
| ODP | Open Drip Proof | |
| OWS | Operator Work Station | |
| P | | Back to Top |
| Pancake | 636 low profile vent termination kit (1HT | |
| Pancake Drier | stout suction line filter driers. ie C-145-S-TT-HH | |
| PC | Performance Contracting | |
| PE | Professional Engineer | |
| Penthouse Unit | they are likely referring to a self-contained refrigeration system that is mounted on the top of a walk-in box. We stock the Bohn Pro3 | |
| PH | Pre-Heat | |
| PID | Proportional Integral Derivative | |
| PRV | Pressure Relief Valve | |
| PRV | Pressure Reducing Valve | |
| PTAC | Packaged Terminal Air Conditioner | |
| Q | | Back to Top |
| R | | Back to Top |
| RA | Return Air | |
| Rezpack/Respack | this is short for “Residential Packaged Unit”. They are a rooftop square in shape that are typically 2-5 tons. In some parts of North America they are used in residential applications. | |
| RF | Return Fan | |
| RH | Reheat | |
| RH | Relative Humidity | |
| RPM | Revolutions Per Minute | |
| RTD | Resistance Temperature Detector | |
| RTU | Roof Top Unit | |
| S | | Back to Top |
| SA | Supply Air | |
| SAT | Supply Air Temperature | |
| SC | Shading Coefficient | |
| SEER | Seasonal Energy Efficiency Ratio | |
| SF | Supply Fan | |
| SHFG | Solar Heat Gain Factor | |
| SHR | Sensible Heat Ratio | |
| Silfos | comes in 5 and 15% silver and is used to bond copper to copper. No flux required | |
| Silver Solder | Silver solder required flux or comes pre fluxed and is used for bonding dissimilar metals | |
| Skeleton Motor | specific style of motor used in small refrigeration applications. | |
| SP | Set Point | |
| SP | Static Pressure | |
| Super Hose | Also known as High Pressure Control Hose. We stock the Ritchie yellow jacket product. Part #: 78712, 78718, 78724, 78730, 78736, 78748, 78760, 78772 | |
| SWP | Steam Working Pressure | |
| T | | Back to Top |
| T | Temperature | |
| T | Thermostat | |
| TEV | Thermostatic Expansion Valve | |
| TOD | Time Of Day | |
| TORR | Millimeter of Mercury (mmHg) | |
| Trax/Traxx Oil/Traxx Oil Control | Trax is an old brand name. The customer is likely looking for a Copeland oil level control – Part #: OMB-JB1 | |
| TXV | Thermostatic Expansion Valve | |
| U | | Back to Top |
| UH | Unit Heater | |
| UV | UltraViolet | |
| UV | Unit Ventilator | |
| V | | Back to Top |
| VAV | Variable Air Volume | |
| VD | Volume Damper | |
| Venter Motor | also known as an inducer motor. It vents harmful gas out of the furnace through pipes to the outside of the house or building | |
| VFD | Variable Frequency Drive | |
| VSD | Variable Speed Drive | |
| VSP | Variable Speed Pump(ing) | |
| W | | Back to Top |
| WB | Wet Bulb | |
| WC | Water Column | |
| Window Shaker | refers to the window mounted air conditioners. We stock Friedrich, and have access to Comfort-aire and Amana | |
| X | | Back to Top |
| Y | | Back to Top |
| YTD | Year To Date | |
| Z | | Back to Top |