A | Back to Top |
AC | Air Conditioning | |
AC | Alternating Current | |
ACH | Air Changes per Hour | |
ACM | Asbestos Containing Material | |
AEE | Association of Energy Engineers | |
AFD | Adjustable Frequency Drive | |
AFUE | Annual Fuel Efficiency Ratio | |
AHU | Air Handling Unit | |
AI | Analog Input | |
Anti-Ice Control | same as a freeze stat or encapsulated pressure control | |
AO | Analog Output | |
Aquastat | controls the use of a water system. We sell the Honeywell aquastats. You can also use the Ranco ETC series of temp controls. | |
ASHRAE | American Society of Heating Refrigeration and Air Conditioning Engineers | |
B | | Back to Top |
B | Boiler | |
BACnet | A Data Communication Protocol for Building Automation and Control Networks | |
BAS | Building Automation System | |
Bazooka | 636 concentric vent kit | |
BCA | Building Commissioning Association | |
Bearshit | cork tape | |
BI | Backward Incline | |
BI | Binary Input | |
BO | Binary Output | |
BSLN | Baseline | |
BTU | British Thermal Unit | |
BTUH | Brtish Thermal Units / Hour | |
BY | Base Year | |
C | | Back to Top |
Can | a small hermetic compressor | |
CAV | Constant Air Volume | |
CD | Cold Deck | |
CDD | Cooling Degree Days | |
CEM | Certified Energy Manager | |
CFC | ChloroFluoroCarbon | |
CFM | Cubic Feet per Minute | |
CH | Chiller | |
CHW | Chilled Water | |
CHWP | Chilled Water Pump | |
CHWR | Chilled Water Return | |
CHWRT | Chilled Water Return Temperature | |
CHWS | Chilled Water Supply | |
CHWST | Chilled Water Supply Temperature | |
CLF | Cooling Load Factor | |
CLTD | Cooling Load Temperature Difference | |
COP | Coefficient Of Performance | |
CRAC | Computer Room Air Conditioner | |
CT | Cooling Tower | |
CV | Constant Volume | |
CVRMSE | Coefficient of Variation of the Root Mean Square of the Error | |
CWP | Condenser Water Pump | |
CWR | Condenser Water Return | |
CWRT | Condenser Water Return Temperature | |
CWS | Condenser Water Supply | |
CWST | Condenser Water Supply Temperature | |
CY | Current Year | |
D | | Back to Top |
DA | Discharge Air | |
DB | Data Base | |
DB | Dry Bulb | |
DC | Direct Current | |
DCV | Demand Controlled Ventilation | |
DD | Degree Day | |
DDC | Direct Digital Control | |
DH | Duct Heater | |
DI | Digital Input | |
DO | Digital Output | |
DP | Dew Point | |
DP | Differential Pressure | |
DX | Direct Expansion | |
E | | Back to Top |
EAT | Entering Air Temperature | |
ECM | Electronically Commutated Motor | |
ECM | Energy Conservation Measure | |
ECO | Energy Conservation Opportunity | |
EDH | Electric Duct Heater | |
EEM | Energy Efficiency Measure | |
EER | Energy Efficiency Ratio | |
EF | Exhaust Fan | |
Eggcrate | this is a plastic grill material that can replace ceiling tiles. Part Number: 2-4-1/2-ALL | |
EH | Electric Heater | |
EMS | Energy Management System | |
ESCO | Energy Service Company | |
EUH | Electric Unit Heater | |
EWT | Entering Water Temperature | |
F | | Back to Top |
FC | Forward Curve | |
FCU | Fan Coil Unit | |
FIM | Facility Improvement Measure | |
Firecracker | Fan cycling control | |
FLA | Full Load Amps | |
Flux | Used to etch metal for filler (solder) to bold | |
FMS | Facility Management System | |
FPM | Feet Per Minute | |
Freeze-Stat | a switch to stop evaporators from icing up. (eg. AE1C-1-ECO or HH) | |
FW | Feed Water | |
G | | Back to Top |
GPM | Gallons Per Minute | |
GUI | Graphical User Interface | |
H | | Back to Top |
HCFC | Hydrochlorocfuorocarbon | |
HD | Hot Deck | |
HDD | Heating Degree Days | |
HEPA | High Efficiency Particulate Arresting | |
HFC | HydroFluoroCarbon | |
HHV | Higher Heating Value | |
HHWP | Heating Hot Water Pump | |
HHWR | Heating Hot Water Return | |
HHWS | Heating Hot Water Supply | |
HL | High Limit | |
HPS | High Pressure Steam | |
HR | Heat Recovery | |
HRU | Heat Recovery Unit | |
HRV | Heat Recovery Ventilator | |
HSPF | Heating Seasonal Performance Factor | |
HVAC | Heating Ventilation and Air Conditioning | |
HWP | Hot Water Pump | |
HWR | Hot Water Return | |
HWS | Hot Water Supply | |
HWRT | Hot Water Return Temperature | |
HWST | Hot Water Supply Temperature | |
HX | Heat Exchanger | |
I | | Back to Top |
I/O | Input Output | |
Inducer Motor | also known as a venter motor. It vents harmful gas out of the furnace through 636 pipe to the outside of the house or building | |
IAQ | Indoor Air Quality | |
IPMVP | International Performance Measurement and Verification Protocol | |
IR | Infra-Red | |
J | | Back to Top |
Jellybean | specific style of crimp connector | |
K | | Back to Top |
King Valve | The shut off valve on a condensing unit. This where refrigerant is charged and where the line set piping connects to | |
L | | Back to Top |
LAT | Leaving Air Temperature | |
LHV | Lower Heating Value | |
Line Voltage Thermostat | Used for electrical baseboards or anything using 120/208v to match amperage. Look for these Honeywell items | |
LL | Low Limit | |
LON | Local Operating Network | |
LP | Low Pressure | |
LPS | Low Pressure Steam | |
LRA | Locked Rotor Amps | |
LWBT | Leaving Wet Bulb Temperature | |
LWT | Leaving Water Temperature | |
M | | Back to Top |
M&V | Measurement and Verification | |
MA | Mixed Air | |
MAT | Mixed Air Temperature | |
MCC | Motor Control Center | |
MUA | Make-up Air Unit | |
Muffin Motor | 3.3" unit bearing motor eg. R-5411 | |
MX | Metrix Utility Accounting System | |
MZ | Multi-Zone | |
N | | Back to Top |
NC | Normally Closed | |
NEMA | National Electrical Manufacturers Association | |
NO | Normally Open | |
NPSH | Net Positive Suction Head | |
O | | Back to Top |
OA | Outside Air | |
OAP | Outside Air Percentage | |
OAT | Outside Air Temperature | |
OCS | this stands for “Our Compressor Shop”. It is referring to internal purchases used for the business. It was called this when RSL operated their own compressor rebuild shop decades ago | |
ODP | Open Drip Proof | |
OWS | Operator Work Station | |
P | | Back to Top |
Pancake | 636 low profile vent termination kit (1HT | |
Pancake Drier | stout suction line filter driers. ie C-145-S-TT-HH | |
PC | Performance Contracting | |
PE | Professional Engineer | |
Penthouse Unit | they are likely referring to a self-contained refrigeration system that is mounted on the top of a walk-in box. We stock the Bohn Pro3 | |
PH | Pre-Heat | |
PID | Proportional Integral Derivative | |
PRV | Pressure Relief Valve | |
PRV | Pressure Reducing Valve | |
PTAC | Packaged Terminal Air Conditioner | |
Q | | Back to Top |
R | | Back to Top |
RA | Return Air | |
Rezpack/Respack | this is short for “Residential Packaged Unit”. They are a rooftop square in shape that are typically 2-5 tons. In some parts of North America they are used in residential applications. | |
RF | Return Fan | |
RH | Reheat | |
RH | Relative Humidity | |
RPM | Revolutions Per Minute | |
RTD | Resistance Temperature Detector | |
RTU | Roof Top Unit | |
S | | Back to Top |
SA | Supply Air | |
SAT | Supply Air Temperature | |
SC | Shading Coefficient | |
SEER | Seasonal Energy Efficiency Ratio | |
SF | Supply Fan | |
SHFG | Solar Heat Gain Factor | |
SHR | Sensible Heat Ratio | |
Silfos | comes in 5 and 15% silver and is used to bond copper to copper. No flux required | |
Silver Solder | Silver solder required flux or comes pre fluxed and is used for bonding dissimilar metals | |
Skeleton Motor | specific style of motor used in small refrigeration applications. | |
SP | Set Point | |
SP | Static Pressure | |
Super Hose | Also known as High Pressure Control Hose. We stock the Ritchie yellow jacket product. Part #: 78712, 78718, 78724, 78730, 78736, 78748, 78760, 78772 | |
SWP | Steam Working Pressure | |
T | | Back to Top |
T | Temperature | |
T | Thermostat | |
TEV | Thermostatic Expansion Valve | |
TOD | Time Of Day | |
TORR | Millimeter of Mercury (mmHg) | |
Trax/Traxx Oil/Traxx Oil Control | Trax is an old brand name. The customer is likely looking for a Copeland oil level control – Part #: OMB-JB1 | |
TXV | Thermostatic Expansion Valve | |
U | | Back to Top |
UH | Unit Heater | |
UV | UltraViolet | |
UV | Unit Ventilator | |
V | | Back to Top |
VAV | Variable Air Volume | |
VD | Volume Damper | |
Venter Motor | also known as an inducer motor. It vents harmful gas out of the furnace through pipes to the outside of the house or building | |
VFD | Variable Frequency Drive | |
VSD | Variable Speed Drive | |
VSP | Variable Speed Pump(ing) | |
W | | Back to Top |
WB | Wet Bulb | |
WC | Water Column | |
Window Shaker | refers to the window mounted air conditioners. We stock Friedrich, and have access to Comfort-aire and Amana | |
X | | Back to Top |
Y | | Back to Top |
YTD | Year To Date | |
Z | | Back to Top |